{"id":3324,"date":"2023-05-02T04:09:07","date_gmt":"2023-05-02T04:09:07","guid":{"rendered":"https:\/\/www.ablenet.co.th\/?p=3324"},"modified":"2023-05-22T07:52:02","modified_gmt":"2023-05-22T07:52:02","slug":"4507rsup8-e_redundant","status":"publish","type":"post","link":"https:\/\/www.ablenet.co.th\/en\/2023\/05\/02\/4507rsup8-e_redundant\/","title":{"rendered":"4507R+Sup8-E_Redundant"},"content":{"rendered":"<p><strong>\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u00a0<\/strong><strong>Core Switch (Catalyst4507R + Supervisor 8E)<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-3904\" src=\"https:\/\/www.ablenet.co.th\/wp-content\/uploads\/2023\/05\/New-Cisco-Catalyst-4500E-Series-Chassis-01.png\" alt=\"\" width=\"617\" height=\"331\" srcset=\"https:\/\/www.ablenet.co.th\/wp-content\/uploads\/2023\/05\/New-Cisco-Catalyst-4500E-Series-Chassis-01.png 617w, https:\/\/www.ablenet.co.th\/wp-content\/uploads\/2023\/05\/New-Cisco-Catalyst-4500E-Series-Chassis-01-300x161.png 300w\" sizes=\"(max-width: 617px) 100vw, 617px\" \/><\/p>\n<p>\u0e40\u0e1b\u0e47\u0e19\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u0e17\u0e35\u0e48\u0e21\u0e35\u0e25\u0e31\u0e01\u0e29\u0e13\u0e30\u0e40\u0e1b\u0e47\u0e19\u0e42\u0e21\u0e14\u0e39\u0e25\u0e32 \u0e41\u0e0b\u0e2a\u0e0b\u0e34\u0e2a (Modular Chassis) \u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a Switching Bandwidth \u0e17\u0e35\u0e48\u0e21\u0e35\u0e04\u0e27\u0e32\u0e21\u0e40\u0e23\u0e47\u0e27\u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 928 Gbps \u0e41\u0e25\u0e30\u0e21\u0e35\u0e04\u0e27\u0e32\u0e21\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e43\u0e19\u0e01\u0e32\u0e23\u0e23\u0e31\u0e1a\u0e2a\u0e48\u0e07\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 48 Gpps<\/p>\n<ol>\n<li>\u0e21\u0e35\u0e0a\u0e48\u0e2d\u0e07\u0e2a\u0e33\u0e2b\u0e23\u0e31\u0e1a\u0e43\u0e2a\u0e48\u0e42\u0e21\u0e14\u0e39\u0e25(Module) \u0e17\u0e31\u0e49\u0e07\u0e2b\u0e21\u0e14\u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 7 \u0e0a\u0e48\u0e2d\u0e07<\/li>\n<li>\u0e21\u0e35 Controller Module \u0e2b\u0e23\u0e37\u0e2d Management Module \u0e2b\u0e23\u0e37\u0e2d Supervisor Module \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 2 Module \u0e40\u0e1e\u0e37\u0e48\u0e2d\u0e40\u0e1b\u0e47\u0e19\u0e2b\u0e19\u0e48\u0e27\u0e22\u0e1b\u0e23\u0e30\u0e21\u0e27\u0e25\u0e1c\u0e25\u0e2a\u0e33\u0e23\u0e2d\u0e07\u0e44\u0e14\u0e49 (redundancy processor)<\/li>\n<li>\u0e21\u0e35\u0e23\u0e30\u0e1a\u0e1a\u0e08\u0e48\u0e32\u0e22\u0e44\u0e1f\u0e02\u0e19\u0e32\u0e14\u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 1400 Watt \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 2 \u0e0a\u0e38\u0e14 \u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e17\u0e33 Redundant Power Supply \u0e44\u0e14\u0e49<\/li>\n<li>\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a\u0e08\u0e33\u0e19\u0e27\u0e19 MAC Address \u0e44\u0e14\u0e49\u0e1e\u0e23\u0e49\u0e2d\u0e21\u0e01\u0e31\u0e19\u0e44\u0e21\u0e48\u0e15\u0e48\u0e33\u0e01\u0e27\u0e48\u0e32 55,000 MAC Address<\/li>\n<li>\u0e2a\u0e19\u0e31\u0e1a\u0e2a\u0e19\u0e38\u0e19\u0e21\u0e32\u0e15\u0e23\u0e10\u0e32\u0e19 IEEE \u0e2d\u0e22\u0e48\u0e32\u0e07\u0e19\u0e49\u0e2d\u0e22\u0e14\u0e31\u0e07\u0e19\u0e35\u0e49 IEEE 802.3, IEEE 802.3u, IEEE 802.3z, IEEE 802.1d, IEEE 802.1p, IEEE 802.1q<\/li>\n<li>\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a Layer 3 Standard Routing \u0e42\u0e1b\u0e23\u0e42\u0e15\u0e04\u0e2d\u0e25 RIP I, RIP II, Static Router, EIGRP,IPv6 \u0e44\u0e14\u0e49\u0e40\u0e1b\u0e47\u0e19\u0e2d\u0e22\u0e48\u0e32\u0e07\u0e19\u0e49\u0e2d\u0e22<\/li>\n<li>\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19\u0e02\u0e2d\u0e07 IPv6 \u0e14\u0e49\u0e27\u0e22 Hardware<\/li>\n<li>\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e02\u0e22\u0e32\u0e22\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19 Layer 3 Enhance Routing \u0e42\u0e1b\u0e23\u0e42\u0e15\u0e04\u0e2d\u0e25 OSPF, EIGRP, BGP4, OSPFv3, EIGRP for IPv6, RIP next generation for IPv6 \u0e43\u0e19\u0e2d\u0e19\u0e32\u0e04\u0e15\u0e44\u0e14\u0e49<\/li>\n<li>\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e17\u0e33 VLAN \u0e44\u0e14\u0e49\u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 4,096 VLAN \u0e15\u0e32\u0e21\u0e21\u0e32\u0e15\u0e23\u0e10\u0e32\u0e19 1Q<\/li>\n<li>\u0e21\u0e35 IP v4 routing entries \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 256,000 \u0e41\u0e25\u0e30 IP v6 routing entries \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 128,000 \u0e41\u0e25\u0e30 \u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a IPv6 MLD Snooping v1 and v2 \u0e40\u0e1b\u0e47\u0e19\u0e2d\u0e22\u0e48\u0e32\u0e07\u0e19\u0e49\u0e2d\u0e22<\/li>\n<li>\u0e21\u0e35 Console \u0e1e\u0e2d\u0e23\u0e4c\u0e15\u0e17\u0e35\u0e48\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e1b\u0e23\u0e31\u0e1a\u0e41\u0e15\u0e48\u0e07\u0e41\u0e25\u0e30\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19\u0e02\u0e2d\u0e07\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u0e44\u0e14\u0e49<\/li>\n<li>\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e17\u0e33\u0e07\u0e32\u0e19\u0e41\u0e1a\u0e1a Port Trunking \u0e41\u0e1a\u0e1a Port Aggregation Protocol (PAgP) \u0e41\u0e25\u0e30 Link Aggregation Control Protocol (LACP) \u0e40\u0e1e\u0e37\u0e48\u0e2d\u0e40\u0e1e\u0e34\u0e48\u0e21\u0e04\u0e27\u0e32\u0e21\u0e40\u0e23\u0e47\u0e27\u0e43\u0e19\u0e01\u0e32\u0e23\u0e2a\u0e48\u0e07\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e44\u0e14\u0e49<\/li>\n<li>\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a Switched Port Analyzer (SPAN) \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 8 sessions \u0e17\u0e31\u0e49\u0e07\u0e0a\u0e19\u0e34\u0e14 ingress and or egress<\/li>\n<li>\u0e15\u0e49\u0e2d\u0e07\u0e21\u0e35\u0e1e\u0e2d\u0e23\u0e4c\u0e15 \u0e14\u0e31\u0e07\u0e15\u0e48\u0e2d\u0e44\u0e1b\u0e19\u0e35\u0e49\n<ol>\n<li>10\/100\/1000 BaseTX \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 48 \u0e1e\u0e2d\u0e23\u0e4c\u0e15<\/li>\n<li>\u0e21\u0e35 SFP slot \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 24 \u0e2a\u0e25\u0e47\u0e2d\u0e15<\/li>\n<li>\u0e21\u0e35 SFP+ slot \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 12 \u0e2a\u0e25\u0e47\u0e2d\u0e15<\/li>\n<\/ol>\n<\/li>\n<li>\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21\u0e41\u0e25\u0e30\u0e08\u0e31\u0e14\u0e01\u0e32\u0e23\u0e40\u0e04\u0e23\u0e37\u0e2d\u0e02\u0e48\u0e32\u0e22\u0e42\u0e14\u0e22\u0e43\u0e0a\u0e49\u0e42\u0e1b\u0e23\u0e42\u0e15\u0e04\u0e2d\u0e25\u0e21\u0e32\u0e15\u0e23\u0e10\u0e32\u0e19 Simple Network Management Protocol (SNMP) \u0e41\u0e25\u0e30\u0e21\u0e32\u0e15\u0e23\u0e10\u0e32\u0e19 Remote Monitoring (RMON) \u0e2d\u0e22\u0e48\u0e32\u0e07\u0e19\u0e49\u0e2d\u0e22 4 Group<\/li>\n<li>\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e1a\u0e23\u0e34\u0e2b\u0e32\u0e23\u0e41\u0e25\u0e30\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21\u0e08\u0e31\u0e14\u0e01\u0e32\u0e23\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u0e19\u0e35\u0e49\u0e1c\u0e48\u0e32\u0e19 Web based \u0e44\u0e14\u0e49<\/li>\n<li>\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e17\u0e33 IP Multicast \u0e42\u0e14\u0e22\u0e43\u0e0a\u0e49\u0e42\u0e1b\u0e23\u0e42\u0e15\u0e04\u0e2d\u0e25 PIM, SSM \u00a0\u0e41\u0e25\u0e30 Distance Vector Multicast Routing Protocol (DVMRP) \u00a0\u0e44\u0e14\u0e49\u0e40\u0e1b\u0e47\u0e19\u0e2d\u0e22\u0e48\u0e32\u0e07\u0e19\u0e49\u0e2d\u0e22<\/li>\n<li>\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e17\u0e33 QoS \u0e41\u0e1a\u0e1a Modular QoS CLI (MQC), Per-port, per-VLAN QoS,<\/li>\n<li>\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e17\u0e33 Auto-QoS command-line interface (CLI)<\/li>\n<li>\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19\u0e41\u0e1a\u0e1a VTP \u0e44\u0e14\u0e49<\/li>\n<li>\u0e44\u0e14\u0e49\u0e23\u0e31\u0e1a\u0e21\u0e32\u0e15\u0e23\u0e32\u0e10\u0e32\u0e19 FCC Part 15 (CFR 47) Class A, UL 60950, IEC 60950, AS\/NZS 3260, AS\/NZS 3548 Class A, NEBS Level 3, ETS 300 019 \u0e40\u0e1b\u0e47\u0e19\u0e2d\u0e22\u0e48\u0e32\u0e07\u0e19\u0e49\u0e2d\u0e22<\/li>\n<li>\u0e1a\u0e23\u0e34\u0e29\u0e31\u0e17\u0e17\u0e35\u0e48\u0e19\u0e33\u0e40\u0e2a\u0e19\u0e2d\u0e08\u0e30\u0e15\u0e49\u0e2d\u0e07\u0e40\u0e1b\u0e47\u0e19\u0e15\u0e31\u0e27\u0e41\u0e17\u0e19\u0e08\u0e33\u0e2b\u0e19\u0e48\u0e32\u0e22\u0e17\u0e35\u0e48\u0e44\u0e14\u0e49\u0e23\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e41\u0e15\u0e48\u0e07\u0e15\u0e31\u0e49\u0e07\u0e08\u0e32\u0e01\u0e2a\u0e32\u0e02\u0e32\u0e02\u0e2d\u0e07\u0e1c\u0e39\u0e49\u0e1c\u0e25\u0e34\u0e15\u0e1b\u0e23\u0e30\u0e08\u0e33\u0e1b\u0e23\u0e30\u0e40\u0e17\u0e28\u0e44\u0e17\u0e22\u0e42\u0e14\u0e22\u0e21\u0e35\u0e40\u0e2d\u0e01\u0e2a\u0e32\u0e23\u0e41\u0e2a\u0e14\u0e07\u0e1e\u0e23\u0e49\u0e2d\u0e21\u0e43\u0e19\u0e01\u0e32\u0e23\u0e22\u0e37\u0e48\u0e19\u0e0b\u0e2d\u0e07\u0e40\u0e2a\u0e19\u0e2d\u0e23\u0e32\u0e04\u0e32<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u00a0Core Switch (Catalyst4507R + Supervisor 8E) \u0e40\u0e1b\u0e47\u0e19\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u0e17\u0e35\u0e48\u0e21\u0e35\u0e25\u0e31\u0e01\u0e29\u0e13\u0e30\u0e40\u0e1b\u0e47\u0e19\u0e42\u0e21\u0e14\u0e39\u0e25\u0e32 \u0e41\u0e0b\u0e2a\u0e0b\u0e34\u0e2a (Modular Chassis) \u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a Switching Bandwidth \u0e17\u0e35\u0e48\u0e21\u0e35\u0e04\u0e27\u0e32\u0e21\u0e40\u0e23\u0e47\u0e27\u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 928 Gbps \u0e41\u0e25\u0e30\u0e21\u0e35\u0e04\u0e27\u0e32\u0e21\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e43\u0e19\u0e01\u0e32\u0e23\u0e23\u0e31\u0e1a\u0e2a\u0e48\u0e07\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 48 Gpps \u0e21\u0e35\u0e0a\u0e48\u0e2d\u0e07\u0e2a\u0e33\u0e2b\u0e23\u0e31\u0e1a\u0e43\u0e2a\u0e48\u0e42\u0e21\u0e14\u0e39\u0e25(Module) \u0e17\u0e31\u0e49\u0e07\u0e2b\u0e21\u0e14\u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 7 \u0e0a\u0e48\u0e2d\u0e07 \u0e21\u0e35 Controller Module \u0e2b\u0e23\u0e37\u0e2d Management Module \u0e2b\u0e23\u0e37\u0e2d Supervisor Module \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 2 Module \u0e40\u0e1e\u0e37\u0e48\u0e2d\u0e40\u0e1b\u0e47\u0e19\u0e2b\u0e19\u0e48\u0e27\u0e22\u0e1b\u0e23\u0e30\u0e21\u0e27\u0e25\u0e1c\u0e25\u0e2a\u0e33\u0e23\u0e2d\u0e07\u0e44\u0e14\u0e49 (redundancy processor) \u0e21\u0e35\u0e23\u0e30\u0e1a\u0e1a\u0e08\u0e48\u0e32\u0e22\u0e44\u0e1f\u0e02\u0e19\u0e32\u0e14\u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 1400 Watt \u0e44\u0e21\u0e48\u0e19\u0e49\u0e2d\u0e22\u0e01\u0e27\u0e48\u0e32 2 \u0e0a\u0e38\u0e14 \u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e17\u0e33 Redundant Power Supply \u0e44\u0e14\u0e49 \u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a\u0e08\u0e33\u0e19\u0e27\u0e19 MAC Address \u0e44\u0e14\u0e49\u0e1e\u0e23\u0e49\u0e2d\u0e21\u0e01\u0e31\u0e19\u0e44\u0e21\u0e48\u0e15\u0e48\u0e33\u0e01\u0e27\u0e48\u0e32 55,000 MAC [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":3327,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[53],"tags":[135,136,63,137],"class_list":["post-3324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tor-spec","tag-catalyst-switch","tag-catalyst4507","tag-cisco","tag-supervisor-8e"],"_links":{"self":[{"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/posts\/3324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/comments?post=3324"}],"version-history":[{"count":2,"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/posts\/3324\/revisions"}],"predecessor-version":[{"id":3905,"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/posts\/3324\/revisions\/3905"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/media\/3327"}],"wp:attachment":[{"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/media?parent=3324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/categories?post=3324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ablenet.co.th\/en\/wp-json\/wp\/v2\/tags?post=3324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}